VAILLANT FAULT CODES
Please note that although the fault code may point you to a certain part that may be faulty, it can sometimes mean that something else is at fault.
The fault codes are only a guide as what to look for
If you have any Vaillant boiler fault codes appear and are unsure how to resolve it, then contact us and arrange for an engineer to call and clear the faults and get your boiler up and running again.
Common Vaillant Fault Codes
Fault Code F00
Heating Flow NTC Thermistor Fault
• The Heating Flow NTC Thermistor Has Become Disconnected Or Has Gone Open Circuit (Should Read 12Kohms @ 20C)
• Wiring Harness Fault Or Connection Error Between The Heating Flow NTC Thermistor And The Main PCB
Fault Code F10
Heating Flow NTC Thermistor Fault
• There Is A Short Circuit On The Heating Flow NTC Thermistor (Should Read 12Kohms @ 20C)
• Wiring Harness Fault Or Connection Error Between The Heating Flow NTC Thermistor And The Main PCB.
Fault Code F11
Heating Return NTC Thermistor Fault
• There Is A Short Circuit On The Heating Return NTC Thermistor (Should Read 12Kohms @ 20C)
• Wiring Harness Fault Or Connection Error Between The Heating Return NTC Thermistor And The Main PCB.
Fault Code F12
Domestic Hot Water Cylinder
NTC Thermistor Fault
(Not Applicable To This Appliance)
Fault Code F13
Internal Domestic Hot Water Storage Tank NTC Thermistor Fault
(Not Applicable To This Appliance)
Fault Code F17
Solar Return Thermistor Fault
(Not Applicable To This Appliance)
Fault Code F20
Overheat Fault
The Flow Or Return Pipe In The Appliance Has Reached 97 Degrees C
Fault Code F22
Low System Water Pressure
• Water Leak Within The Boiler
• Water Leak Within The System
• The Pressure Relief Valve Has Activated Due To An Expansion Related Issue - Check Expansion Vessel & Heating System Water Volume
Fault Code F23
Maximum Temperature Differential Across The Heating Flow & Return Has Been Reached (35 Degrees C)
• Inadequate Pump Operation
• Blockage Or Air Lock Within The Appliance (No Water Movement)
• Blockage Or Air Lock In The Heating System (No Water Movement)
• Check Domestic Hot Water Heat Exchanger and Domestic Hot Water Heat Exchanger Filter For Debris If Fault Occurs On Hot Water Mode Only
• Check Resistance On The Heating Flow & Return NTC Thermistors To Ensure Accurate Temperature Monitoring (Should Read 12K ohms @ 20C)
Fault Code F24
Water Circulation Fault (Temperature Rise Greater Than 10 Degrees Celsius Per Second)
• Inadequate Pump Operation
• Isolation Valves Closed Under The Appliance
• Blockage Or Air Lock Within The Appliance (No Water Movement)
• Blockage Or Air Lock In The Heating System (No Water Movement)
• Check Domestic Hot Water Heat Exchanger and Domestic Hot Water Heat Exchanger Filter For Debris If Fault Occurs On Hot Water Mode Only
• Check Resistance On The Heating Flow & Return NTC Thermistors To Ensure Accurate Temperature Monitoring (Should Read 12K ohms @ 20C)
Fault Code F25
Flue Gas Temperature Too High (Not Applicable To UK Models)
Fault Code F27
Incorrect Flame Detection Fault (Flame Detection Even Though The Gas Valve Is Off)
• Damage On The Electrode Or The Ignition Lead
• Moisture Present On The Electronics
• Fault On The Spark Generator
• Fault On The Main PCB
Fault Code F28
Ignition Failure
• Insufficient Inlet Working Gas Pressure To The Appliance
• Flue Problem
• Bad Earth Connection
• Incorrect Gas Valve Adjustment
• Debris Within The Heat Engine (Burner Etc)
• Electrode Or Ignition Lead Fault
• Spark Generator Fault
• Faulty Gas Valve
Fault Code F29
Flame Failure During Operation
• Insufficient Inlet Working Gas Pressure To The Appliance
• Flue Problem
• Incorrect Gas Valve Adjustment
• Debris Within The Heat Engine (Burner Etc)
• Electrode Or Ignition Lead Issue
• Spark Generator Fault
• Faulty Gas Valve
Fault Code F32
Air Fault – (Fan Or Flue)
• Blockage In The Flue System
• Fan Rotation Speed Incorrect (Power To Fan But Fan Not Running)
• Loose Connection On The Wiring Harness Between The Fan And The Main PCB
Fault Code F33
Air Pressure Switch Fault – (Not Applicable To UK Models)
Fault Code F49
eBUS Voltage Error (Glow Worm Heating Controls Only)
• Overload On eBUS Connection On Main PCB
• Check External Glow Worm eBUS Heating Controls
• Check Wiring Between Glow Worm eBUS Controls And The Main PCB
• Check For Correct eBUS Output Voltage (22vdc) From Main PCB
Fault Code F61
Gas Valve Fault
• Loose Or Damaged Electrical Connection Between The Gas Valve & The Main PCB
• Faulty Gas Valve
• Main PCB Fault
Fault Code F62
Gas Valve Closure Fault
• Flame Presence Still Detected After A Demand Has Ceased Due To The Gas Valve Not Shutting Down Correctly (Gas Valve Fault - Passing)
• Fault On Electronics (Power To The Gas Valve With No Demand)
Fault Code F63
Main PCB Memory Fault
• Loose Or Damaged Electrical Connection On The Main PCB
• The User Interface PCB Has Not Been Set Up Correctly By The Service Engineer (Incorrect Product Code Has Been Entered)
• Main PCB Fault
Fault Code F64
Rapid Fluctuation Of Heating Flow Or Return NTC Thermistors Due To Electrical Errors
• Loose Or Damaged Electrical Connections Between The Flow Or Return NTC Thermistors And The Main PCB
• Inconsistent Resistance On Heating Flow Or Heating Return NTC Thermistor Due To Thermistor Failure
• Main PCB Fault
Fault Code F65
Main PCB Temperature Too High
• Mains Input Voltage Problem
• Damaged Or Loose Electrical Connection On The Main PCB
• Main PCB Fault
Fault Code F67
Flame Signal Fault On The Main PCB
• Damaged Or Loose Electrical Connection On The Main PCB
• Main PCB Fault
• Mains Input Voltage Problem (Reverse Polarity, Poor Earth Etc)
Fault Code F68
Fluctuation Of Flame Signal
• Insufficient Inlet Working Gas Pressure To The Appliance
• Flue Problem
• Incorrect Gas Valve Adjustment (Poor Combustion)
• Debris Within The Heat Engine (Burner Etc)
• Electrode Or Ignition Lead Fault
• Spark Generator Fault
• Faulty Gas Valve
Fault Code F70
Incompatible Software
• Replacement User Interface PCB Has Not Been Set Up Correctly By The Service Engineer
• User Interface PCB Fault
• Main PCB Fault
Fault Code F71
Heating Flow NTC Thermistor Disconnected Or Defective (No Temperature Change When Burner Lit)
• Heating Flow NTC Thermistor Is Not Connected To The Flow Pipe On The Main Heat Exchanger Correctly
• Defective Heating Flow NTC Thermistor
Fault Code F72
Permanent Temperature Difference Between Heating Flow & Return NTC Thermistors (Thermistor Error)
• The Heating Flow NTC Thermistor Is Reading The Incorrect Resistance (Should Read 12Kohms @ 20C)
• Wiring Harness Fault Or Connection Error Between The Heating Flow NTC Thermistor And The Main PCB
• The Heating Return NTC Thermistor Is Reading The Incorrect Resistance (Should Read 12Kohms @ 20C)
• Wiring Harness Fault Or Connection Error Between The Heating Return NTC Thermistor And The Main PCB
• The Thermistors Have Been Reversed (Connected To The Wrong Pipes)
Fault Code F73
Low Water Pressure Sensor Fault
• Broken, Loose Or Damp Electrical Connection On The Wiring Harness Between The Low Water Pressure Sensor And The Main PCB
• Low Water Pressure Sensor Fault
Fault Code F74
Low Water Pressure Sensor Fault
• Broken, Loose Or Damp Electrical Connection On The Wiring Harness Between The Low Water Pressure Sensor And The Main PCB
• Low Water Pressure Sensor Fault
Fault Code F75
Low Water Pressure Sensor Fault Or Pump Proving Issue
• Low Water Pressure Sensor Faulty Or Blocked With System Debris
• Pump Not Running (Water Pressure Sensor Needs To See A 50 mBar (0.05 Bar) Pressure Increase On Pump Start Within 10 Seconds)
• Flow Filter Blocked With Debris
• Expansion Vessel Air Charge Insufficient
Fault Code F76
Thermal Fuse Failure - Heat Exchanger Has Reached 160 Degrees C
(Not Applicable To UK Models)
Fault Code F77
External Glow Worm Condensate Pump Fault
• Condensate Blockage
• Fault With Glow Worm Condensate Pump Or Associated Wiring
Fault Code F78
Compatibility Error Between The Boiler And The Glow Worm eBUS System Controls
• The Glow Worm eBUS System Controls Are Not Compatible With The Boiler
• Wiring Fault Between The Boiler And The Glow Worm eBUS System Controls
• Glow Worm eBUS System Controls Fault
• Loose Or Damaged Wiring Connection On The Main PCB
• Main PCB Fault
Fault Code F83
Insufficient Temperature Increase Once Burner Is Lit
• Low System Water Pressure
• Flow Or Return NTC Thermistors Out Of Calibration (Should Read 12Kohms @ 20C) Or Not Connected To Pipework Correctly
• Damaged Or Loose Connections On The Wiring Loom Between The NTC Thermistors And The Main PCB
• Low Heat Input Into The Heat Exchanger – Poor Thermal Performance Caused By Low Gas Rate, Incorrectly Adjusted Gas Valve, Or Restriction/Poor Heat
Transfer Within The Combustion Chamber
Fault Code F84
Permanent Temperature Difference Between Heating Flow & Return NTC Thermistors (Thermistor Error)
• The Heating Flow NTC Thermistor Is Reading The Incorrect Resistance (Should Read 12Kohms @ 20C)
• Wiring Harness Fault Or Connection Error Between The Heating Flow NTC Thermistor And The Main PCB
• The Heating Return NTC Thermistor Is Reading The Incorrect Resistance (Should Read 12Kohms @ 20C)
• Wiring Harness Fault Or Connection Error Between The Heating Return NTC Thermistor And The Main PCB
• The Thermistors Have Been Reversed (Connected To The Wrong Pipes)
Fault Code F85
Flow Or Return NTC Thermistor Fault
• The Flow & Return NTC Thermistors Are Both Connected To The Same Pipe (Reading The Same Temperature)
• Faulty Flow Or Return NTC Thermistor
Fault Code F86
Overheat Thermostat From 3rd Party Underfloor Heating Control Has Activated (If Fitted)
• Check For Circulation Issues On Any Underfloor Heating Circuits
• If No 3RD Party Underfloor Overheat Thermostat Is Fitted To The Boiler, Check That The Link Wire Is Fitted Into The “B.off” Connection On Terminal X41 On The
Main PCB
Fault Code F87
Electrode Fault
• Faulty Ignition Electrode Or Ignition Lead
Fault Code F88
Electrical Fault On The Gas Valve Circuit
• Loose Or Damaged Connection On The Wiring Harness Between The Main PCB and The Gas Valve
• Faulty Gas Valve (Short Circuit)
Fault Code F89
Electrical Fault On The Pump Circuit
• Loose Or Damaged Connection On The Wiring Harness Between The Pump and The Main PCB
• Faulty Pump (Short Circuit)